欢迎访问泰克产品支持
虽然我们很愿意与您全天“讨论技术问题”,但我们知道您时间宝贵。因此,我们简化了流程,让您可以轻松下载所有当前产品以及许多停产产品的手册、产品技术资料和软件。只需告诉我们您使用的是哪种产品,我们就会向您显示所有相关信息。
您选择的产品型号当前有售。 提供了以下支持信息。
-
产品技术资料 文献编号: 发布日期 P6900系列DDR存储器应用产品技术资料
52W-29275-1 Tektronix Logic Analyzer Probes
Verification and debug of today's high speed digital signals requires probing solutions that can accurately acquire from a wide variety of electronic designs and protect signal fidelity. Tektronix logic analyzer probes contain a variety of …52W-29212-4 P6800/P6900 Series Logic Analyzer Datasheet
52W-17703-13
-
手册 手册类型 部件号: 发布日期 China RoHS Supplemental, 071217907
Product Information Sheet for People's Republic of China Other用户 071217907 TLP058
FlexConnect Logic Probe Instructions主要用户 071351500 Tektronix Supplemental
Product Information Sheet for People's Republic of China Other用户 071329302 Tektronix Supplemental Product Information Sheet
People’s Republic of China Other用户 071217901 TLP058 FlexChannel Logic Probe Instructions
FlexChannel Logic Probe主要用户 071351503 Probes and Accessories Declassification and Security Instructions
Declassification and Security解密 071238400 Tektronix Supplemental, 071329304
Product Information Sheet for People‚s Republic of China用户 071329304 P5910-P5934-P5960-Probe Datasheet
52W-29212-2 TLA6400 Series
Specifications & Performance Verification Technical Reference性能验证 077063401 P5960
DMAX Logic Analzyer Probe Instruction Manual用户 077063701 P5910
General Purpose Logic Analzyer Probe Instruction Manual用户 077063501 P5934
Mictor Logic Analzyer Probe Instruction Manual主要用户 077063600 P6900 Series User Manual
High-Density Logic Analyzer Probes with D-Max Probing Technology主要用户 077152806 P6960HCD and P6960HCD-LV Probe Instructions
Probe现场安装说明 071261201 TLA7BXX Series Specifications and Performance Verification Manual
Logic AnalyzersProduct Specifications & Performance Verification性能验证 077014801 P5934 Mictor Probe
Installation Instructions Instructions用户 071297500 P5960 D-MAX Probe
Installation Instructions Instructions用户 071297600 P6960DBL and P6962DBL User Manual
High-Density Logic Analyzer Probes with D-Max Probing Technology主要用户 077247901 P6960DBL Labeling and Installation Instructions
High Density Single-Ended Logic Analyzer Probe with D-Max Probing Technology Labeling and Installation现场安装说明 071245500 P69xx Series Probes Alternate Retention Assembly Installation Instructions
Probes Alternate Retention Assembly主要用户 071239400 Read This First
Windows XP Operating System用户 071165101 P6982 Labeling and Installation Manual
17 Channel Differential Logic Analyzer Probe Optimized for 2X Demultiplexing Installation Manual用户 071168401 P6810 Instructions
General Purpose Logic Analyzer Probe Label Instructions用户 071112200
-
技术文档 文档类型 发布日期 Tektronix 示波器附件选择指南
示波器探头相互参考, 无源探头, 有源探头, 差分探头和差分前置放大器, 电流探头, 高压探头和高压差分探头, 连接器和适配器, 光电转换器, 衰减器, 端接器和电缆, 仪器手推车/机架安装套件, 探头尖附件产品选择指南 Serial Analyzers for PCIe 2.0 Provide Power Management and Cross Bus Analysis
产品文章 P6860 Memory Parts List
Click on this link to download the P6860 memory list.合规性 P6810 Memory Parts List
Click on this link to download the P6810 memory list.合规性 P6880 Memory Parts List
Click on this link to download the P6880 memory list.合规性 Serial Analyzers Deliver Comprehensive PCIe Testing
产品文章 Tektronix delivers complete DDR memory test bench
产品文章 Verify and debug DDR2 memory systems
技术简介
-
常见问题 常见问题 ID Will the P6516 Logic Probe work on my MSO4000B, MDO4000B and MDO4000C Series oscilloscopes?
The P6516 logic probe was only used with the original MSO4000 series. For the subsequent MSO4000B, MDO4000B and MDO4000C Series oscilloscopes, the P6516 was replaced by the P6616 logic probe. The P6616 logic probe will not work on the original …246206 I need to determine the maximum thickness circuit board that is compatible with the P6900 series probes using the wire clips included with the retention posts. What is the length of the retention post wire clips?
Two sets of wire clips are included with the retention post kit. The shorter clip will extend .180” below the base of the post and the longer set will extend .310” below the base of the post.60826 I'm using a P6419/P68xx probe and it came with a thick and a thin elastomer. How do I know which one I should use?
If the PCB thickness is 1.27 mm to 2.36 mm (0.050 in to 0.093 in), use the nut bar with the thin elastomer. If the PCB thickness is 2.36 mm to 3.81 mm (0.093 in to 0.150 in), use the press-in nut with the thick elastomer. See more probes »52876 What probes can be used with the TLA7Lx+ TLA7Mx+ TLA7Nx+ TLA7Px+ TLA7Qx+ TLA6xx+ TLA520x and TLA520xB?
The following probes can be used with these modules: P6410, P6417, P6418, P6419, P6434, and P645057876 What is the advantage to buying a P6982 probe instead of a P6980 probe?
The P6982 is exactly the same as the P6980 except that it has only one 17-ch probe head so the total number of channels is 17 instead of 34. A customer would order the P6982 if they are only using quarter or half channels for (4x or 2x clocking). In …57741 What probes can be used with the TLA7NAx+ TLA7Axx or TLA7BBx modules?
The following probes can be used with the TLA7NAx, TLA7Axx or TLA7BBx modules: P6810, P6860, P6864, P6880, P6960, P6962, P6964, P6980 and P6982.57881 What is the diameter of the wire that is included in the retention post kit for the P6900 series probes?
The wire diameter is .024".61231 For general purpose probing why would I choose the P6810 over the P6960 with the optional general purpose leadset?
The P6960 probe can serve well as a general purpose probe with the optional leadset but it’s important to note that any flying leadset will restrict bandwidth because of the added additional loading. While the P6810 can be used with leadsets as well …55511 Are the P6810+ P6860+ P6864+ P6880+ P6960+ P6962+ P6964+ P6980+ P6982 probes compatible with our Logic Analyzer?
The P6800 and P6900 series probes are not compatible with TLA5200/B series, TLA600 series or TLA7Lx/Mx/Nx/Px/Qx Logic Analyzer modules. They are compatible with TLA7AAx/ABx/NAx/BBx modules.57126 Is the footprint for the P68xx and P69xx (DMAX) the same size?
No, the footprint for the P69xx or DMAX probes is about 61% smaller.57466 What is the TLAHRA?
The TLAHRA is a high resistance 18 channel adapter that provides 10Mohm impedance and works with the P6410, P6417, P6418, and P6810 general purpose probes.57861 Why would I choose the P6419 over the other P6400 series probes?
The P6419 probe is a connector less probe that compresses onto pads that have been laid out on a board under test. Advantages are ease of connection to a run of circuit boards and reduced expense not having to install square pins or other connectors …56306 Are my Agilent LA and Tektronix Logic analyzer probes compatible?
Tektronix probes do not work with Agilent Logic Analyzers and iView will not work with Agilent Scopes or Logic Analyzers.57121 Where can I find design specifications for the P68xx footprint?
All design specifications, electrical characteristics, and probe channel mapping can be found in the manual for the P68xx series probes.57946 Where can I find design specifications for the P69xx DMAX footprint?
All design specifications, electrical characteristics, and probe channel mapping can be found in the manual for the P69xx series probes, available for download at the following link.57951 Are the P6400/P6800/P6900 series logic analyzer probes active?
There is no active circuitry in the P6410(general-purpose 17 channel probe), the P6417 (general-purpose 17 channel probe), P6418 (17 channel general-purpose probe), P6419 (17 connectorless compression probe) or P6434 (high-density 34 channel probe) …60376 Is there an option to using the retention posts for the P6960+ P6962+ P6964+ P6980 or the P6982?
Yes there is an Alternate Retention Assembly. You can order them as a pair, part number 020-2908-00 or as a set of 50, part number 020-2910-00. For reference enter 071239400 and 077152804 into the search window at http://www.tek.com62026 How Do I Set Up a Parallel Bus Decode?
For doing Parallel Bus decode Tektronix recommends using a MSO or MDO + MSO option Series oscilloscopes. This feature comes standard in the Bus menu and can be used in a variety of ways. Start by turning it on, selecting the channel and setting your …64771 How closely matched are the P6400 series probes?
The time delay specifications are the same on every P6400 series probe (P6410,P6417, P6418, P6419 and P6434 probes). This allows you to mix probe types on the same logic analyzer, thereby preserving accurate data correlation from the probe tip of …60671 How do I declassify or sanitize my instrument?
Declassification and Security documents for many Tektronix products are located in the Download, Manuals and Documentation on Tek.com. /node/7106. Enter your instrument model number and select Download Type as "Manuals". At the results screen, on …55686 Is there a difference in board layout between press-in nut (PIN) and nutbar?
Yes, the PIN layout has a slightly larger hole than if you use the nutbar.3.50 mm (0.138 in) diameter thin PCB with nut bar.3.73 mm (0.147 in) diameter thick PCB with press in nut.52941 How do I get more retention posts for the P6960+ P6962+ P6964+ P6980 or the P6982?
The replacement kit can be ordered with part number 020-2539-00. This kit contains one black post, one silver post, and two sets of mounting wires (long and short) for different PCB thicknesses.52586 How closely matched are the connectorless and D-Max probes?
The time delay specifications are the same on every P6800 series probe (P6810, P6860, P6864 and P6880 probes) and every P6900 series probe (P6960, P6980, and P6982 probes). This allows you to mix probe types on the same logic analyzer, thereby …57281 Is there an adapter to connect my P6434 probes to my onboard P6960 (D-Max) footprint?
Yes, Nexus makes an adapter (NEX-P6960M) that will allow a P6434 probe to connect to the P6960 (D-Max) connector. Please visit Nexus for details.57531 Is there a Mictor adapter that connects to the P6410+ P6417+ P6418 or P6810?
Yes, Nexus makes an adapter (NEX-HD2HEADER) that will allow a P6410, P6417, P6418 or P6810 probe to connect to the mictor connection on the board. NEXUS57496 Is there an adapter available to connect my general purpose probes (P6410+ P6417+ P6418+ P6810) to the DMAX (P6960 ) footprint?
Yes, our partner Nexus provides this adapter. See http://www.nexustechnology.com/products/laAccessories/p6960pin/63856 The signal mapping of my on board Mictor for P6434 is not equal to the mapping required for the support package. How can I re-wire the signals to meet the support package mapping?
Nexus offers a Adapter called the NEX-HDSWIZ for re-wiring Mictor connectors on a target for connection to Tektronix P6434 High Density Probes. It provides the ability to rewire all 38 connectors. Please visit Nexus for details.56011 Is the layout for the press-in nut (PIN) the same as the nutbar when using the P68xx series probes?
No, the hole for the PIN hole is larger.3.50 mm (0.138 in) diameter thin PCB with nut bar.3.73 mm (0.147 in) diameter thick PCB with press in nut.52921 Is the Soft Touch Pro footprint the same as the D-Max (P6900) footprint?
Yes, they are identical. Although, the regular soft touch is not the same as our connectorless compression probe (P6800) footprint.57476 How do I set up a CAN bus decode?
Depending on the scope you have, the available options for decoding your CAN signal will depend on the compatibility. For all the DPO/MSO2000/3000/4000/5000 and MDO3000/4000 Series scopes, there are modules or license keys specifically designed for …64751 Are there IBIS or Spice loading models available for your Logic Analyzer probes?
Unfortunately we do not have pre-developed IBIS/Spice Models using the information provided in the P68xx probe manual.52351 Why do the input channels on my TLA float to 2.2 volts?
The P6410, P6417, P6418 and P6434 probes have probe loading characteristics of 20kohm to 2.2V*. This is why the signal may be pulled to to 2.2V around the signal transitions. An optional Reduced Bias Voltage lead set (part number 196-3477-00 for 8 …57961 Why would I choose the P6434 over the other P6400 series probes?
The P6434 probe is a high density probe that uses a Mictor connector from AMP. It takes up ¼ of the space on a circuit board compared to the other probes in P6400 series. The trade off is a mating Mictor connector needs to be engineered into your …56311 What is the pin size supported for P6410+ P6417+ P6418 and P6810 probes?
The pin type is 0.025" inch square. For larger pins a SMG50 will need to be used. The pin spacing supported is .1 inch and 2 mm.56141 What size pins are the P6410+ P6417+ P6418+ P6810 and P6960 probe leadsets designed for?
These probes are designed for .025" square pins. If the pins are larger, you will need to use the SMG 50. See more probes »57896 The P6419/P68xx probe manuals mention a thick and a thin PCB. How do I know which one I have?
If the PCB thickness is 1.27 mm to 2.36 mm (0.050 in to 0.093 in), use the nut bar with the thin elastomer.If the PCB thickness is 2.36 mm to 3.81 mm (0.093 in to 0.150 in), use thepress-in nut with the thick elastomer.53046 Do the P68xx and the P69xx probes work with OSP (Organic Surface Protectant) board finish?
Tektronix recommends immersion gold surface plating for all P68xx probes. Some customers have experienced success with immersion Silver and HASL surface finishes for the P68xx series probes. While we continue to recommend immersion Gold as the best …57221 Do you have an application note that explains how and when to use a logic analyzer? Is there a tutorial that will show me how to use my logic analyzer?
The XYZ's of Logic Analyzers explains the evolution from the digital oscilloscope to the logic analyzer. It explains the capabilities of a logic analyzer and will you choose the correct tool for your particular application. The Introduction to …55406 Can I use a differential probe on a single ended signal?
Yes, if you ground the negative lead of the differential signal on the probe to ground.57166 Can the P6316, P6516, or P6616 logic probes be used interchangeably?
The simple answer is no they can't be used interchangeably. The front end of the logic channels are different so different logic probes are needed between the scopes. For MSO2000/B, MSO3000, and MDO3000 Series oscilloscopes, only the P6316 logic …59166