What options are mandatory on a VM6000 instrument?

问题:

What options are mandatory on a VM6000 instrument?

答案:

A new VM6000 requires purchase of at least one of Option. SD , HD or VGA.

Most customers need both SD and HD to fully test component analog interfaces, thus instruments can also be configured with SD and HD.

Option SS or the individual signal sets listed below are required if you do not already have a copy of the version 2 signal sets from a VM5000.

Option SS Signal Sources Package Includes:

Part No.DescriptionFormats
020-2770-00Signal Sources DVD480i, 576i
020-2771-001Standard Definition Elementary Streams 480i, 480p, 576i, 576p
020-2772-00Advanced Definition Elementary Streams720P, 1080i, 1080p
020-2773-002ATSC Transport Streams480i, 480p, 720P, 1080i, 1080p
020-2774-003,4,5Baseband Test Signals525i, 525p, 625i, 625p, 720p, 1080i, 1080p,
020-2775-006PC Bit map Graphics620x480, 800x600, 1024x768, 1280x1024, 1600x1024, 1600x1200, 1920x1080, 1920x1200, 1920x1440, 2048x1536, 2048x2048
020-2776-00H.264 SD&HD Streams480i, 480p, 576i, 576p, 720p, 1080i, 1080p

1 480i, 480p ES stream provided by 704*480, 720*480 resolution.
2 ATSC transport stream provided for 480i, 480p, 720p/30, 720p/60, 1080i/60, 1080p/24, and 1080p/ 59.94 formats.
3 Requires TG700 & appropriate module (AVG7, AWVG7, DVG7, and/or HDVG7).
4 SDI signal generation not supported for 525P, 576p format.
5 TG700 DNL files not provided for 1080p/50 and 1080p/60 formats.
6 Includes PC Matrix and Full Field VESA Signals.