My ISA Board Works When I Take Just a Single Sample, but Does Not When Sampling at a Rate

问题:

My ISA Board Works When I Take Just a Single Sample, but Does Not When Sampling at a Rate

答案:

If the board returns correct data when taking single samples but fails to operate satisfactorily when acquiring data at a programmed rate, there is probaby an interrupt or DMA channel conflict. The single sample mode does not require the use of an interrupt or DMA transfer. When a pacer clock is used to control the rate at which data are acquired, the IRQ and/or DMA are necessary to coordinate these transfers. Sound cards often present DMA conflicts. Network or even video cards often conflict with interrupt settings.

此常见问题适用于:

无产品系列

产品:

常见问题 ID 70806