问题:
Can I use the SRA-01 with the KPCMCIA-PIO24-C?
答案:
This is not a recommended configuration. The KPCMCIA-PIO24-C does not provide the necessary 5VDC power from the computer that the logic chips on the SRA-01 accessory requires. There is no easy way to integrate the use of an external power supply.
The SSIO-24 is an alternate backplane for solid state relays. The SSIO-24 uses the miniature relays (SM-ODC, etc.). When used with the KPCMCIA-PIO24-C, an external 5VDC power supply is required for the SSIO-24.
此常见问题适用于: