联系我们

与泰克代表实时聊天。 工作时间:上午 9:00 - 下午 5:00(太平洋标准时间)。

电话

致电我们

工作时间:上午9:00-下午5:00(太平洋标准时间)

下载

下载手册、产品技术资料、软件等:

下载类型
型号或关键字

反馈

50 Ω TekVPI to TekConnect Probe Adapter

TCA-VPI50 Datasheet

更多信息

在线阅读:

TCA VPI50 51W276353
TCA-VPI50 Datasheet

Expand the functionality of Tektronix high-performance oscilloscopes

The TCA-VPI50 adapter extends the functionality of the TCA Series of adapters by enabling 50 Ω TekVPI probes to be used on oscilloscopes with TekConnect interfaces. The TekVPI interface is used on bench and performance oscilloscopes from 100 MHz up to 3.5 GHz, and until now, TekVPI probes could only be used on oscilloscopes that have a TekVPI Probe Interface. The TCA-VPI50 will only work with 50 Ω terminated probes. It will not work with 1 MΩ terminated probes, examples of which are passive probes, current probes, and most high-voltage probes.

Features and benefits

  • Use 50 Ω TekVPI Probes on DPO/DSA/MSO70000 Series Oscilloscopes
  • Bandwidth – DC to 4 GHz
  • 50 Ω Input (Only)

Applications

  • High-speed Digital Systems Design
  • Component Design and Characterization
  • Manufacturing Engineering and Test
  • Educational Research
  • Design, Validation, Debugging, and Characterization of Common High-speed Serial Bus Designs
  • Signal Integrity, Jitter, and Timing Analysis
  • Manufacturing Engineering and Test

Specifications

All specifications are typical unless noted otherwise. All specifications apply to all models unless noted otherwise.

Characteristics

Bandwidth (–3 dB)
DC to 4 GHz (Adapter Only)
Input Resistance at DC
50 Ω
Propagation Delay (Input-to-Output)
<300 ps
VSWR (Return Loss)
1.15 max
RF Insertion Loss
0.25 dB max (Adapter Only)
RMS Noise
Refer to Host Instrument Specification
Maximum Input Voltage
Refer to Host Instrument Specification
Inputs
1 (TekVPI 50 Ω)

Supported oscilloscopes

MSO/DPO/DSA70000C/D/DX and DPO70000SX (Windows 7 or Windows 10 with Firmware 6.2.0 or later required)

Supported probes

  • TekVPI 50 Ω
    • TIVH02/TIVH02L/TIVH05/TIVH05L/TIVM1/TIVM1L/TIVH08/TIVH08L
    • TAP1500/TAP2500/TAP3500/TAP4000
    • TDP0500/ TDP1000/TDP1500/TDP3500/TDP4000
  • TekVPI 1 MΩ probes are not supported

Ordering information

TCA-VPI50
TekConnect-to-TekVPI 50 Ω Adapter.

Service options

Opt. C3
Calibration Service 3 Years
Opt. C5
Calibration Service 5 Years
Opt. CA1
Single Calibration or Functional Verification
Opt. R3
Repair Service 3 Years (including warranty)
Opt. R5
Repair Service 5 Years (including warranty)
Opt. SILV200
Standard warranty extended to 5 years

Additional Service Products Available During Warranty (DW) or Post Warranty (PW)

TCA-VPI50-CA1
Provides a single calibration event or coverage
TCA-VPI50-R1PW
Repair Service Coverage 1 Year Post Warranty
TCA-VPI50-R2PW
Repair Service Coverage 2 Years Post Warranty
TCA-VPI50-R3DW
Repair Service Coverage 3 Years (includes product warranty period). 3-year period starts at time of customer instrument purchase
TCA-VPI50-R5DW
Repair Service Coverage 5 Years (includes product warranty period). 5-year period starts at time of customer instrument purchase