联系我们

与泰克代表实时聊天。 工作时间:上午 9:00 - 下午 5:00(太平洋标准时间)。

电话

致电我们

工作时间:上午9:00-下午5:00(太平洋标准时间)

下载

下载手册、产品技术资料、软件等:

下载类型
型号或关键字

反馈

GPIB-LAN Adapter

AD007

泰克对于本技术资料上的产品不再有售。
查看 Tektronix Encore 了解翻新测试设备。
查看这些产品的支持保修状态

Features & Benefits

  • Control Tektronix Oscilloscopes and Other Instruments via a LAN-Based (Ethernet) TCP/IP Network PC
  • Interface Up to 14 GPIB Devices to Each AD007
  • Talk to Several GPIB Instruments/Systems from Several Networked PCs
  • Print to Networked Printers
  • Ethernet Twisted Pair (10Base-T) Adapter
  • Operates on All Microsoft Windows 95/98 and NT 4.0 Operating Systems
  • Compatible with WaveStar for Oscilloscopes Applications Software and Custom, Proprietary Programs (C, C++, or Microsoft Visual Basic)
  • Compact Size
  • Web Page-based Configuration and Statistics

Applications

  • Digital Design
  • Research and Development
  • Manufacturing Test
  • Service and Support
  • Education

Instrument to Local Area Network (LAN) Connectivity

Control your Tektronix TDS Series oscilloscope from any networked PC. Check on its status or capture waveforms any time you want from your office, another site, or from anywhere using WaveStar application software or your own software. Or command your TDS Series oscilloscope to print to a networked printer.

The Tektronix GPIB-LAN adapter takes advantage of the fact that many of today's computers are connected together through an Ethernet 10Base-T LAN.

Print to Networked Printers

Using any web browser, select the networked printer to which your TDS Series oscilloscope will print and route your hardcopy output to your high quality monochrome or color networked printer.

A000_0584-N

Several GPIB-networked instruments can be connected using the AD007 Adapter to LAN (Ethernet)-based computers and printers.
 
Microsoft Windows 95/98/2000 or NT 4.0 Compatibility

You do not need to understand or program Ethernet protocols. Both communications and Virtual Instrument Software Architecture (VISA) software for Microsoft Windows 95/98/2000 or NT 4.0 are included free with the GPIB-LAN adapter. Now, you can also perform waveform capture from your TDS Series oscilloscopes across the LAN by using Tektronix WaveStar™ for oscilloscopes application software. Or write a program using C, C++, or Microsoft Visual Basic to capture data or control your instrument. As long as the program is written using the standard VISA interface, the GPIB-LAN adapter's software will turn your PC into a GPIB talker, listener, controller.

Network Details

The AD007 implements a full range of adapter functions and Ethernet-based TCP/IP protocols. It operates with all of the popular network protocols such as BOOTP, DHCP, DNS, LPD, HTTP and FTP.

Configuration and Statistics

Use a web browser to configure features; examine GPIB commands, Ethernet traffic statistics, and GPIB traffic statistics; and initiate diagnostic GPIB commands.

Ease of Installation

Simply connect your AD007 to your LAN with the cable provided, connect the GPIB interface to your instruments and power up the unit. It automatically requests an IP address from the network's boot server or this can be manually entered using the adapter's internal web page. Upon power-up, the unit also performs hardware diagnostics/self-test. Status indicators on the unit give evidence of successful completion of this testing, connection to the LAN and both LAN and GPIB traffic.

Any number of AD007 Adapters may be used to connect any combination of GPIB devices to the network. (NOTE: Limit of 14 devices per GPIB cluster.)

Characteristics

System Requirements

Computer Type - IBM PC-compatible with Microsoft Windows 95/98 or NT 4.0 Operating System. Consult Microsoft documentation for recommended configuration.

Hard Disk - 5 MB or greater.

RAM - Consult Microsoft documentation for recommended minimum configuration.

CD-ROM - Required.

NOTE: For printing, only a web browser is required.

 

Network Compatibility

Ethernet Port - 10Base-T, RJ-45 connector.

Protocols - BOOTP, DHCP, LPD, DNS, HTTP, FTP.

Networked Printer -

Compatibility: Must be compatible with the GPIB instrument's hardcopy output format.

Print Protocol: Must support LPD Network Print protocol.

 

IEEE 488 (GPIB) Compatibility

Connection - No cable required for most applications.

Compatibility - Fully IEEE488.2 compatible.

NOTE: Not suitable for connection to the public telecommunications (telephone) network.

 

Other

Transmission Rate - Up to 10 Mb/s on Ethernet; dependent on slowest GPIB device on the bus.

Front-panel Indicators - Power, LAN-Link, LAN, GPIB.

Environmental

Temperature -

Operating: 0 °C to +45 °C.

Nonoperating: -20 °C to +70 °C.

 

Humidity - 30 °C to 45 °C, 90 to 95%, relative humidity.

Altitude -

Operating: up to 2,000 m (6,500 ft.).

Nonoperating: up to 10,000 m (33,000 ft.).

 

Vibration - 3 axis, 60 minutes total, 20 minutes/axis (10 minutes operating, 10 minutes nonoperating).

Shock - Half sine, 500 g, 3 axis, 3 drops each axis.

EMC Compliance

Meets the intent of EMC directive 89/336/EEC.

Complies with FCC part 15, class A limits.

Safety Compliance (power supply only)

EN60950 (CE Mark).

UL1950.

CAN/CSA 22.2 No. 950.

DENTORI (T-MARK).

Power

Source Power -

Voltage ranges: 100 to 240 VAC ±10%.

Line frequency: 50 to 60 Hz.

 

Power Consumption - Regulated 5 VDC at 300 mA, typical.

Physical Characteristics

Physical Characteristics

Dimensions

mm

in.

Weight

kg

lb.

Height

35.6

1.4

Width

76.2

3

Depth

120.2

4.7

Net

0.15

0.34

Warranty

One year parts and labor.

Ordering Information

AD007

GPIB-LAN Adapter.

Includes: Adapter, regulated power supply, CD-ROM software, RJ-45 cable, manual.

Please specify power plug when ordering.

Power Plug Options

Opt. A0 - US Plug, 115 V, 60 Hz

Opt. A1 - Euro Plug, 220V, 50 Hz

Opt. A2 - UK Plug, 240V, 50 Hz

Opt. A3 - Australian Plug, 240V, 50 Hz

Opt. A5 - Swiss Plug, 220V, 50 Hz

Opt. A6 - Japanese Plug, 100V, 110/120 Volt, 60 Hz

Service

Opt. R3 - Repair Service 3 Years

Opt. R5 - Repair Service 5 Years