Specifications
All specifications are guaranteed unless noted otherwise. All specifications apply to all models unless noted otherwise.
Compatible with TLA7AAx, TLA7ACx, TLA7NAx, TLA7BBx, TLA7BCx, and TLA6200
P6860 | P6910 | P6960 | P6962/P6964 | P6980 | P6982 | |
---|---|---|---|---|---|---|
Data | Single-ended | Differential | Single-ended | Single-ended | Differential | Differential |
Clock | Differential | |||||
Number of channels | 34 | 34 | 34 | 34 | 34 | 17 |
Recommended use | Good signal density and quick reliable attachment. Not recommended for new designs. Use P6960 for new designs. | General-purpose applications | Best signal density and quick reliable attachment. Flying leads for general-purpose probing is optional. | Data rates in excess of 750 MHz (TLA7Bxx) or 450 MHz (TLA7ACx) with the best signal density. | Full differential probing with the best signal density. | Full differential with the best signal density for data rates in excess of 750 MHz (TLA7Bxx) or 450 MHz (TLA7ACx). |
Attachment to target system | Compression Elastomer | Fits 0.100 in. square pin configurations; flying-leads, solder-in | D-Max® probing technology compression cLGA | D-Max® probing technology compression cLGA | D-Max® probing technology compression cLGA | D-Max® probing technology compression cLGA |
Probe specifications
- Input resistance
-
20 kΩ to Ground, typical
- Input capacitance
-
- P6860
- P6910
- 1.3 pF
- All others
- 0.5 pF
- Minimum digital swing
-
- TLA7AAx/TLA7ACx
-
P6910 P6860, P6960, P6962, P6964 P6980, P6982 150 mV single-ended 300 mV single-ended 150 mV differential each side - TLA7BBx/TLA7BCx
-
P6910 P6860, P6960, P6962, P6964 P6980, P6982 100 mV single-ended 200 mV single-ended 100 mV differential each side
- Analog bandwidth 1
-
- With TLA7Bxx module
- 3 GHz through iCapture™ to analog out BNCs
- With TLA7ACx module
- 2 GHz through iCapture™ to analog out BNCs
1Analog bandwidth of the P6960 probe is less with the flying lead set attached.
- Operating range
- -2 V to +5 V
- Maximum nondestructive voltage
- ±15 V
- Cable length
- 1.8 m (6 ft.)